The following is being proposed for preliminary review and comment only:
1. For Preliminary Review Only: Revise Scope, Section 1, and Materials, Section 3, to Clarify Requirements Covered or Not Covered in UL 136
2. For Preliminary Review Only: Clarify Fire and Electric Shock Requirements in UL 136; and Revise Load Test Methods, and Clarify Cover Removal Requirements in Section 9
3. For Preliminary Review Only: Clarify Non-Evaluations of Removal and Replaceable Parts in UL 136
4. For Preliminary Review Only: Revise Cover Test Requirements in Section 4, Assembly
5. For Preliminary Review Only: Revise Steam Release Requirements for Primary and Secondary Relief Devices in Section 4, Assembly
6. For Preliminary Review Only: Delete Clogging Reference, and Revise Weight-loaded Type Valve Requirements in Section 5, Pressure Reliefs
7. For Preliminary Review Only: Revise Pressure-Indicating Device Requirements in Section 6, Clarify Test Requirements in Section 9, and Clarify Pressure Cooker Test Requirements in Section 11
8. For Preliminary Review Only: Clarification of Abnormal Heat Supply, and the Maximum Operating Pressure for Testing in Sections 7 and 8
9. For Preliminary Review Only: Delete Duplicate Requirement from Section 7, Maximum and Normal Operating Pressure and Leakage Test
10. For Preliminary Review Only: Clarify Body Height Test Requirement in Section 7, Maximum and Normal Operating Pressure and Leakage Test
11. For Preliminary Review Only: Clarify Top Burner Test Requirements for Section 7, Maximum and Normal Operating Pressure and Leakage Test
12. For Preliminary Review Only: Revise Load Test Methods in Section 9, Cover Opening Test
13. For Preliminary Review Only: Clarify Cover Removal Requirements in Section 9, Cover Opening Test
14. For Preliminary Review Only: Clarify Test Methods in Section 9, Cover Opening Test
15. For Preliminary Review Only: Clarify Pressure Cooker Test Requirements in Section 11, Hydrostatic Strength Test
16. For Preliminary Review Only: Clarify Supplementary Means Test Requirement in Section 11, Hydrostatic Strength Test
17. For Preliminary Review Only: Add New Section 6A, Handles; and Section 11A, Handle Temperature Test, to Provide New Test and Temperature Limit Requirements for Handles