The following topics are being recirculated:
6. Revisions to add the moisture meter as an alternate means of determining red oak moisture content in 5.9.
9. Revisions to remove the requirements for a chart recorder and the plotting of temperature in 6.7.
10. Revisions to remove the requirements for a chart recorder and allowance for soot accumulation on the photocell in 7.1.6.