This revision to ANSI/UL 8750 includes the following changes in requirements:

• Revise definition for dead conductive part

• Revise risk of electric shock definition

• Allowance for LED drivers to comply with UL 935

• Remove restriction requiring epoxy material for potting compound in 6.6.1

• Clarify requirements for asphalt potting compounds

• Add exception to 7.1.2 to allow gold or aluminum conductive materials on trace conductors and electrical connections

• Revise 7.3.4 to include provisions for solder connections using solder reflow method

• Add additional wire types for power limited circuit wiring

• Add requirements for transformer or coil insulation systems that operate above Class 105(A) limits

• Clarify requirements for Class 2 output circuits

• Revise Table 8.1 to include temperature limits for switches, terminal blocks, connectors and other discrete devices

• Revise requirements involving cheesecloth to include fire indicator material

• Revise requirements for leakage current measurement test in Section 8.7

• Environmental tests and Class 2 applications

• Marking provisions

• Revise coil insulation requirements to allow triple insulated wiring in transformers/inductors

• Add test oven specification for temperature test

• Miscellaneous and minor proposed revisions to clarify original requirements